Vented, 280 Bar Maximum Setting SCBV1
GENERAL DESCRIPTION
- Load holding to 3000 psi with 4000 psi valve setting
- Maximum valve leakage at reseat = 0.4 cc/min.
- Reseat exceeds 85% of set pressure
- Factory pressure setting established at 32.8 cc/min.
- Free flow check cracking pressure = 40 psi
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Adjustment Range - 'YO' is standard set at 3000 psi
- Pilot Ratio - 3:1