philda final logo

 

 

  • Home
  • About Us
  • Supplier Relations
  • Products
    • Mechanical Seals
      • API Seals
      • Pusher Seals
      • Catridge Seals
      • Elastomer Bellow Seals
      • Metal Bellow Seals
      • Engineered Seals
      • Split Seals
      • Agitator Seals
      • Compressor Seals
      • Seal Supply Systems
    • Industrial Valves
      • Industrial Hydraulic Valves
        • Pressure Control Valves
        • Flow Control Valves
        • Modular Valves
        • Check Valves
        • Directional Control Valves
        • Oil Filters
      • Screw-In-Cartridge Valves
        • Relief Catridge Valves
        • Sequence Cartridge Valves
        • Pilot Operated Check Cartridge Valves
        • Free Flow Check Cartridge Valves
        • Counter Balance Cartridge Valves
      • Mobile Hydraulic Valves
        • Multiple Section Directional Valves
    • Carbon Brush
    • Cables & Accessories
    • Customized Parts & Eqpts
    • Precision Machining
    • Power Generators
  • Services
    • Government
    • Procurement
    • Logistics
  • Careers
  • Feedback
  • Contact Us

Counter Balance Cartridge Valves

  • 280 Bar Maximum Setting SCBV1
  • 350 Bar Maximum Setting SCBV2
  • 350 Bar Maximum Setting SCBV3
  • 420 Bar Maximum Setting SCBV4

texcoBrand

 

  • Print
  • Email

Vented, 280 Bar Maximum Setting SCBV1

GENERAL DESCRIPTION
  1. Load holding to 3000 psi with 4000 psi valve setting
  2. Maximum valve leakage at reseat = 0.4 cc/min.
  3. Reseat exceeds 85% of set pressure
  4. Factory pressure setting established at 32.8 cc/min.
  5. Free flow check cracking pressure = 40 psi
  6. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  7. Adjustment Range - 'YO' is standard set at 3000 psi
  8. Pilot Ratio - 3:1
 