texcoBrand

 

Standard, 350 Bar Maximum Setting SCBV3

GENERAL DESCRIPTION
  1. Load holding to 4000 psi with 5000 psi valve setting
  2. Maximum valve leakage at reseat = 0.4 cc/min.
  3. Reseat exceeds 85% of set pressure
  4. Factory pressure setting established at 32.8 cc/min.
  5. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  6. Back pressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the back pressure.
  7. Adjustment Range - 'RR' is standard set at 3000 psi
  8. Pilot Ratio - 2.3:1