texcoBrand

 

Direct Acting SRV1

GENERAL DESCRIPTION
  1. Maximum operating pressure = 5000 psi
  2. Cannot be adjusted with pressure at Port 1.
  3. Will accept maximum pressure at Port 2.
  4. Back pressure on the tank port (port 2) is directly additive at a 1:1 ratio to the valve setting.
  5. Factory pressure settings established at 15 L/min.
  6. Typical response time 2 ms.
  7. Maximum leakage = 0.7 cc/min. at reseat.
  8. Reseat exceeds 90% of cracking pressure.
  9. Adjustment Range = 'RH' & 'YO' are standard set at 1000 psi